The GSM Power Facility Alarm system with 8 routes of wired input alarm.Monitor 3 phase loss voltage and single phase failure of the electric distribution network.Can connect line-cut/movement/vibration sensors etc., It will alarm when power transformer is damaged or moved.
Send SMS to 6 preset mobile phone numbers automatically while alarming.
Auto-dial 2 preset phone numbers and monitor the alarm site while alarming.
- With 8 routes of wired input alarm.
- Monitor 3 phase loss voltage and single phase failure of the electric distribution network.
- Can connect line-cut/movement/vibration sensors etc., It will alarm when power transformer is damaged or moved.
- Send SMS to 6 preset mobile phone numbers automatically while alarming.
- Auto-dial 2 preset phone numbers and monitor the alarm site while ala
rming.
- Can program the alarm host and inquiry its status by SMS demand
- Can report the communication status of alarm host in fixed time everyday.
- Can set fixed-time arm/disarm.
- Completely sealed aluminum outer shell: waterproof, anti-corrosion, fireproof, strike preventing which are suitable for outdoor installation.
- Resist electromagnetic interference, lighting and thunder(New)
- The system has power-off protection function. When the external power supply is damaged or the power is off, the system can continue to work with a backup battery.
- Can install the solar battery that can supply the power for alarm host and charge the backup battery.(New)
- External power failure alarm: when the system checks out that there is something wrong with the external power or the external power is off for more than 2 seconds, it will alarm immediately
- Can connect with the alarm center through GSM network.
Specification
- GSM frequency: 900/1800MHZ or 850/1900MHZ ( GSM WAVECOME Module)
The frequency of Model No.G30E: 900/1800MHZ
The frequency of Model No.G30EA: 850/1900MHZ
Note: only the GSM frequency is different between the two models.
- Output Mode
- SMS data output
- Auto-dialed voice output
- Alarm response time: 8s,GSM is in normality
- Siren volume: 110 db
- Electric power network: connect mode: Y
Phase-Neutral rated work voltage: AC220V
Phase-Neutral lowest work voltage: AC110V
Phase-Neutral highest work voltage: AC270V
- Biggest capacity of insurance tube: 3A
- Standby battery: DC12V/1.2AH
or DC12V/1AH,Ni-MH battery
- Anti- electromagnetic interference: IEC55022
- Insulation level: grade B
- Protection level: IP55
- Temperature: -10-+55
Humidity: 95% (non-condensation)