Model: G30E
The GSM Power Facility Alarm system with 8 routes of wired inputs. Monitor 3 phase loss voltage and single phase failure of the electric distribution network.Can connect line-cut/movement/vibration etc., It will alarm when power transformer is damaged or moved.Send SMS to 6 preset celll phone numbers automatically while alarming.Auto-dial 2 preset phone numbers and monitor the alarm site while alarming.
Wireless GSM Industrial Alarm System
Main Features
• With 8 routes of wired input alarm.
• Monitor 3 phase loss voltage and single phase failure of the electric distribution network.
• Can connect line-cut/movement/vibration sensors etc., It will alarm when power transformer is damaged or moved.
• Send SMS to 6 preset mobile phone numbers automatically while alarming.
• Auto-dial 2 preset phone numbers and monitor the alarm site while ala
rming.
• Can program the alarm host and inquiry its status by SMS demand
• Can report the communication status of alarm host in fixed time everyday.
• Can set fixed-time arm/disarm.
• Completely sealed aluminum outer shell: waterproof, anti-corrosion, fireproof, strike preventing which are suitable for outdoor installation.
• Resist electromagnetic interference, lighting and thunder(New)
• The system has power-off protection function. When the external power supply is damaged or the power is off, the system can continue to work with a backup battery.
• Can install the solar battery that can supply the power for alarm host and charge the backup battery.(New)
• External power failure alarm: when the system checks out that there is something wrong with the external power or the external power is off for more than 2 seconds, it will alarm immediately
• Can connect with the alarm center through GSM network.
Main Unit PARAMETER
• GSM frequency: 900/1800MHZ or 850/1900MHZ ( GSM WAVECOME Module)
The frequency of Model No.G30E: 900/1800MHZ
The frequency of Model No.G30EA: 850/1900MHZ
Note: only the GSM frequency is different between the two models.
• Output Mode
1) SMS data output
2) Auto-dialed voice output
• Alarm response time: 8s,GSM is in normality
• Siren volume: 110 db
• Electric power network: connect mode: Y
1) Phase-Neutral rated work voltage: AC220V
2) Phase-Neutral lowest work voltage: AC110V
3) Phase-Neutral highest work voltage: AC270V
• Biggest capacity of insurance tube: 3A
• Standby battery: DC12V/1.2AH
or DC12V/1AH,Ni-MH battery
• Anti- electromagnetic interference: IEC55022
• Insulation level: grade B
• Protection level: IP55
• Temperature: -10-+55
• Humidity: 95% (non-condensation)